Home Auto Repair 2006 Ford Mustang GENERATOR Service Manuals

2006 Ford Mustang GENERATOR Service Manuals

66
Download Removal and Installation 1. Disconnect the battery. 2. Press the lock tab, remove the crankcase vent tube from the air cleaner outlet pipe and place it aside. 3. Loosen the clamp, remove the air cleaner outlet pipe from the throttle physique and position it aside. 4. Rotate the entrance finish accessory drive belt tensioner clockwise and position the entrance finish accessory drive belt aside. 5. Take away the 2 generator bolts. To install, tighten to 25 Nm (18 lb-ft) . 6. Take away the 2 outer generator bracket bolts and place the generator aside. To install, tighten to 10 Nm (89 lb-in) . 7. Take away the 2 inside generator bracket bolts. To put in, tighten to 10 Nm (89 lb-in) . 8. Remove the generator harness locator and take away the generator bracket. 9. Disconnect the generator electrical connector. 10. Position the generator B+ protective boot aside, remove the nut and position the generator B+ terminal aside. To install, tighten to eight Nm (71 lb-in) . 11. Remove the generator. 12. To put in, reverse the elimination procedure.